Part Number Hot Search : 
HMS87 CD40175B 3256A TDE8715D IR210 2SK29 1204C 090814
Product Description
Full Text Search
 

To Download DCD40A Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  104 condor d.c. power supplies, inc., 2311 statham parkway, oxnard, ca 93033 800-235-5929 ? 805-486-4565  fax 805-487-8911  www.condorpower.com dcx40 dc/dc converters input dcd models: 24 vdc, 18-32 vdc; dcg models: 48 vdc, 36-72 vdc. hold-up time 6msec minimum from loss of dc input at full load, nominal line. output power normal continuous output power is 40 w (45 w pk) for 60 sec. output regulation regulation for multiple-output models measured by 40% load changefrom 60% rated load with all other outputs at 60% full rated load and a line voltage change from low line to high line. initial set tolerance is measured with all outputs at 60% of full rated load. output voltage v1 requires 20% load for proper regulation of multiple-output models. regulation for single-output models measured by changing load from 5% load to 50% load or 50% load to full load in either direction. remote sense standard on single-output versions. capable of compensating for 0.25 v total of cabling losses in the output voltage. overload protection fully protected against short circuit and output overload. short circuit protection is cycling type power limit on outputs #1 and #2; foldback type on output #3. factory set to begin power limiting at approximately 55 w. no load turn-on/standby no degradation of reliability will occur; however, regulation may be affected. output noise and ripple 0.5% rms, 1.5% pk-pk, 20 mhz bandwidth, differential mode. measured with scope probe directly across output terminals of the power supply with load terminated with 0.1 f capacitor. transient response main output; 500 sec typical response time for return to within 0.5% of final value for a 50% load step within the regulation limits of minimum and maximum load, ? i/ ? t<0.2/sec. maximum voltage deviation is 3.5%. overvoltage protection built in on v1 with firing point set per output ratings table. ovp firing reduces outputs 1 and 2 to less than 50% of nominal voltage in 50 msec. voltage adjustment factory set on standard units. however, optional potentiometer adjusts voltage from 4.7 v to ovp point (6.2 v nominal) on the +5 v output. note: output #1 must not be more than 1% below nominal to achieve full output voltage range on output #2. output regulation limits in some models may be exceeded when the main output is adjusted beyond +/- 1% of nominal voltage. see output ratings chart for additional notes and conditions. high voltage settings may degrade the reliability of the unit due to excessive power dissipation in some outputs. consult factory for application assistance. efficiency 68% minimum at full rated load, nominal input voltage, depending upon model and load distribution. single-output models = 72% to 80% depending upon model. overshoot less than 3% at turn-on under nominal conditions, inversely proportional to input voltage and temperature. less than 2% overshoot at turn-off under all conditions. turn-on time less than 1 sec. at nominal line, 25 c (inversely proportional to input voltage and thermistor temperature). input protection internal fuse provided on all units. inadvertent reverse voltage application will blow fuse without risk of fire or shock hazard. otherwise, internal fuse is designed to protect against cata- strophic circuit failures. fuse does not blow on overload or short circuit. inrush current inrush is limited by internal thermistors to 22 a pk @ 24 vdc and 44 a pk @ 48 vdc. temperature coefficient 0.03%/ c typical on all outputs. environmental designed for 0 to 50 c operation at full rated output power; derate output current and total output power by 2.5% per c above 50 c. see environmental and packing specification on next page. storage -40 to +85 c. emi compliance all models include built-in emi filtering to meet or exceed the emissions requirements of fcc class b. cispr 22-class b. typical margins >3db at all frequencies and line/load conditions. safety all dcx models are approved to ul 1950 (with no d4 deviations), csa22.2 no. 234 level 3, iec950, en60950. features  40 w dc/dc converter  same size as ac input version  drop-in replacement for glc40 series  two input ranges: 24 v and 48 v  two-year warrranty  full off-line isolation  single and multiple output versions available  marked to lvd specifications:
105 condor d.c. power supplies, inc., 2311 statham parkway, oxnard, ca 93033 800-235-5929  805-486-4565  fax 805-487-8911  www.condorpower.com dcx40 dc/dc converters a. to maintain these regulation conditions, the 5.1 v current must be at least 20% of v2 and not greater than five times the v2 current, and requires +5.1 v to be adjusted within 1%, with at least a 0.4 a load. b. replace ? x ? with ? d ? for 24 vdc input or ? g ? for 48 vdc input. dcx40 mechanical specifications ) b ( l e d o m . o n t u p t u o t u p t u o d a o l m u m i n i m t n e r r u c n o i t a l u g e r l a t o t p v o e s i o n d n a e l p p i r s e t o n a 0 4 x c d1v 1 . 5 +a 4 . 0a 4% 2v 6 . 0 2 . 6% 1 2v 2 1 +a 2 . 0a 2% 6% 1a 3v 2 1 -a 0a 4 . 0% 5% 1 b 0 4 x c d1v 1 . 5 +a 4 . 0a 4% 2v 6 . 0 2 . 6% 1 2v 5 1 +a 2 . 0a 2% 6% 1a 3v 5 1 -a 0a 4 . 0% 5% 1 d 0 4 x c d1v 1 . 5 +a 4 . 0a 4% 2v 6 . 0 2 . 6% 1 2v 4 2 +a 1 . 0a 1% 6% 1a 3v 2 1 -a 0a 4 . 0% 5% 1 5 - 0 4 x c d1 a 8 . 7% 2v 6 . 0 2 . 6% 1 2 1 - 0 4 x c d1 a 3 . 3% 2v 1 . 1 4 1% 1 5 1 - 0 4 x c d1 a 7 . 2% 2v 5 . 1 5 . 8 1% 1 4 2 - 0 4 x c d1 a 7 . 1% 2v 5 . 2 8 2% 1 8 2 - 0 4 x c d1 a 4 . 1% 2v 8 . 2 4 3% 1 dimensions: inches millimeters l a t n e m n o r i v n e n o i t a c i f i c e p s g n i t a r e p o g n i t a r e p o - n o n ) a ( e r u t a r e p m e t0 5 o t 0 o c5 8 + o t 0 4 - o c ) a ( y t i d i m u hh r % 5 9 o t 0h r % 5 9 o t 0 ) b ( k c o h sg 0 2 k p g 0 4 k p e d u t i t l at f 0 0 0 , 0 1 o t 0 0 5 -t f 0 0 0 , 0 4 o t 0 0 5 - ) c ( n o i t a r b i vg 5 . 1 s m r g 3 0 0 . 0 , 2 z h /g 5 s m r g 6 2 0 . 0 , 2 z h / a. units should be allowed to warm up/operate under non-condensing conditions before application of power. derated output current and toal output power by 2.5% per o c above 50 o c. b. random vibration ? 10 to 2000hz, 6db/octave roll-off from 350 to 2000hz, 3 orthogonal axes. tested for 10 min./axis operating and 1 hr./axis non-operating. c. shock testing ? half-sinusoidal, 10 3 ms duration, direction, 3 orthogonal axes, total 6 shocks.


▲Up To Search▲   

 
Price & Availability of DCD40A

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X